Abstract

A technique based on measurement of change of natural frequencies has been employed to detect multiple cracks in long pipes containing fluid at different pressures. The cracks have straight fronts and are non-leaking. Both theoretical and experimental results are presented. Two different materials, aluminium and mild steel, have been examined. The fluid considered is water; three (gauge) pressures in the range 0–981 kPa, and crack size to thickness ratio in the range 0.19–0.64 are studied. Two simultaneous cracks are considered in the experiments. The crack locations are predicted with an error less than 4.3%. Results on crack-equivalent rotational spring stiffness, which can be useful in the calculation of natural frequencies and crack size predictions, are reported.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.