Abstract

Abstract Steady-State Visually Evoked Potentials (SSVEP) manifest as a sustained rhythmic activity that can be observed in surface electroencephalography (EEG) in response to periodic visual stimuli, commonly referred to as flickers. SSVEPs are widely used in fundamental cognitive neuroscience paradigms and Brain-Computer Interfaces (BCI) due to their robust and rapid onset. However, they have drawbacks related to the intrusive saliency of flickering visual stimuli, which may induce eye strain, cognitive fatigue, and biases in visual exploration. Previous findings highlighted the potential of altering features of flicker stimuli to improve user experience. In this study, we propose to reduce the amplitude modulation depth of flickering stimuli down to the individuals’ perceptual visibility threshold (periliminal) and below (subliminal). The stimulus amplitude modulation depth represents the contrast difference between the two alternating states of a flicker. A simple visual attention task where participants responded to the presentation of spatially-cued target stimuli (left and right) was used to assess the validity of such periliminal and subliminal frequency-tagging probes to capture spatial attention. The left and right sides of the screen, where target stimuli were presented, were covered by large flickers (13 and 15 Hz respectively). The amplitude modulation depth of these flickers was manipulated across three conditions: control, periliminal, and subliminal. The latter two levels of flickers amplitude modulation depth were defined through a perceptual visibility threshold protocol on a single- subject basis. Subjective feedback indicated that the use of periliminal and subliminal flickers substantially improved user experience. The present study demonstrates that periliminal and subliminal flickers evoked SSVEP responses that can be used to derive spatial attention in frequency-tagging paradigms. The single-trial classification of attended space (left versus right) based on SSVEP response reached an average accuracy of 81.1% for the periliminal and 58% for the subliminal conditions. These findings reveal the promises held by the application of inconspicuous flickers to both cognitive neuroscience research and BCI development.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.