Abstract

Middle ear disease is the primary cause of hearing loss in children and has a significant impact on language development and academic performance. Multiple prognostic factors have previously been examined, but there is little published data regarding frequency-specific hearing outcomes. To examine the relationship between type I tympanoplasty in a pediatric population and frequency-specific hearing changes, as well as the relationship between several prognostic factors and graft retention. Retrospective medical chart review (February 2006 to October 2011) of 492 consecutive pediatric otolaryngology patients undergoing type I tympanoplasty for tympanic membrane (TM) perforation of any etiology at a tertiary-care pediatric otolaryngology practice. Type I tympanoplasty. Preoperative and postoperative audiometric data were collected for patients undergoing successful TM repair. It was hypothesized before data collection that conductive hearing would improve at all frequencies with no significant change in sensorineural hearing. Data collected included air conduction at 250 to 8000 Hz, speech reception thresholds, bone conduction at 500 to 4000 Hz, and air-bone gap at 500 to 4000 Hz. Demographic data obtained included sex, age, size, mechanism, location of perforation, and operative repair technique. Of 492 patients, 320 were excluded; results were thus examined for 172 patients. Surgery was successful for 73.8% of patients. Perforation size was significantly associated with repair success (mean [SD] surgical success rate of 38.6% [15.3%] vs surgical failure rate of 31.4% [15.0%]; P < .01); however, mean (SD) age (9.02 [3.89] years [surgical success] vs 8.52 [3.43] years [surgical failure]; P > .05) and repair technique (medial [73.08%] vs lateral [76.47%] graft success; P > .99) were not. Air conduction significantly improved from 250 to 2000 Hz (P < .001), did not significantly improve at 4000 Hz (P = .08), and there was a nonsignificant decline at 8000 Hz (P = .12). Speech reception threshold significantly improved (20 vs 15 dB; P < .001). This large review found an association of TM perforation size with surgical success and an improvement in speech reception threshold, air conduction at 250 to 2000 Hz, air-bone gap at 500 to 2000 Hz, and worsening bone conduction at 4000 Hz. Patients with high-frequency hearing loss due to TM perforation should not anticipate significant recovery from type I tympanoplasty. Hearing loss at higher frequencies may require postoperative hearing rehabilitation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.