Abstract
Frequency shifts of an optical Nd : YAG/I2-standard are measured in a pressure range of molecular iodine 5 – 22 mTorr and deviation of probe modulation frequency 480 kHz – 4 MHz for the hyperfine structure component a1 of the molecular iodine absorption line R(56) 32 – 0. The frequency shift of the optical standard is estimated under varied temperatures of a cell and cell finger, which determines the pressure of the molecular iodine vapour. The requirements are defined to temperature stability of the cell and its finger for obtaining high long-term frequency stability of the optical frequency standard.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.