Abstract

Simplified expressions describing the frequency response of eddy correlation systems due to sensor response, path-length averaging, sensor separation and signal processing are presented. A routine procedure for estimating and correcting for the frequency response loss in flux and variance measurements is discussed and illustrated by application to the Institute of Hydrology's ‘Hydra’ eddy correlation system. The results show that flux loss from such a system is typically 5 to 10% for sensible and latent heat flux, but can be much larger for momentum flux and variance measurements in certain conditions. A microcomputer program is included which, with little modification, can be used for estimating flux loss from other eddy correlation systems with different or additional sensors.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.