Abstract
A frequency measurement method based on signal delay detection is presented. The method adopts multi-path same delay line to generate multi-path delayed signal whose period is almost the same with that of the reference signal, the average delay time of two adjacent signals that are detected is selected as the interval between the reference signal's rising edge and gate's opening and closing time to calculate the frequency of the measured signal. Error analysis and measurement uncertainty evaluation show that the precision of measurement of the method is determined by the delay time. Experimental data verify that the method could ensure testing speed while effectively reduce the error of ± 1 count.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.