Abstract

High quality factor ($Q$) nanomechanical resonators have received a lot of attention for sensor applications with unprecedented sensitivity. Despite the large interest, few investigations into the frequency stability of high-$Q$ resonators have been reported. Such resonators are characterized by a linewidth significantly smaller than typically employed measurement bandwidths, which is the opposite regime to what is normally considered for sensors. Here, the frequency stability of high-$Q$ silicon nitride string resonators is investigated both in open-loop and closed-loop configurations. The stability is here characterized using the Allan deviation. For open-loop tracking, it is found that the Allan deviation gets separated into two regimes, one limited by the thermomechanical noise of the resonator and the other by the detection noise of the optical transduction system. The point of transition between the two regimes is the resonator response time, which can be shown to have a linear dependence on $Q$. Laser power fluctuations from the optical readout is found to present a fundamental limit to the frequency stability. Finally, for closed-loop measurements, the response time is shown to no longer be intrinsically limited but instead given by the bandwidth of the closed-loop tracking system. Computed Allan deviations based on theory are given as well and found to agree well with the measurements. These results are of importance for the understanding of fundamental limitations of high-$Q$ resonators and their application as high performance sensors.

Highlights

  • As the size of a mechanical resonator is minimized, the responsivity towards changes in the resonator environment is increased [1,2]

  • The frequency stability of high-Q silicon nitride string resonators is investigated both in open-loop and closed-loop configurations

  • We investigate the frequency stability of high-Q nanomechanical string resonators made from silicon nitride (SiN)

Read more

Summary

INTRODUCTION

As the size of a mechanical resonator is minimized, the responsivity towards changes in the resonator environment is increased [1,2]. Roy et al reported enhanced frequency stability in resonators made from silicon, when Q is lowered as the SNR is increased, operating at the onset of Duffing nonlinearity in a thermomechanically limited regime [25]. This was attributed to a flattening of the phase noise spectrum at low frequencies. We investigate the frequency stability of high-Q nanomechanical string resonators made from silicon nitride (SiN) Such resonators routinely achieve large Qs as a result of the dissipation dilution effect [27,28,29]. All Allan deviation measurements are corroborated by computations based on a theoretical model [26] and good agreement is observed both for open loop and closed loop

Measurement setup
Allan deviation
Sources of noise
Influence of signal-to-noise ratio in open-loop configuration
Influence of quality factor in open-loop configuration
Closed-loop tracking