Abstract

ABSTRACTA horizontal transmitter loop (vertical magnetic dipole) is used for frequency electromagnetic (FEM) soundings. The frequency ranges from approximately 6 Hz to about 4000 Hz. The vertical and radial magnetic field components are measured for 20 frequencies per decade several hundred meters from the transmitter loop. A very small bandwidth is selected for amplification using a reference signal. An Apple computer is used for data acquisition.A computer program for Marquardt inversion optimizes the parameters for the n‐layer case: the resistivities and thicknesses of individual beds and a correction factor for the primary magnetic field. Interpretation of each component individually yields practically the same parameters. Examples from the field are given with interpretation; comparison with dc resistivity measurements is provided.The ratio of vertical/radial magnetic field components vs. frequency can be transformed simply into apparent resistivity vs. apparent depth. This can be done in the field to obtain an estimation of the depth of the layer boundaries. FEM results are compared with Schlumberger d.c. sounding obtained at the same site.