Abstract

During frequency controller design, the system frequency dynamic behavior is normally assessed by a system frequency response (SFR) model, which is a linearized low-order model that can be efficiently handled. Existing SFR models for a system with wind turbines cannot precisely characterize the nonlinear dynamic of fast frequency controllers in these turbines, causing inaccurate evaluation of the system frequency behavior that may lead to undesired design of fast frequency control parameters. To deal with this issue, the linearization error of the SFR model is formally analyzed. A compensation strategy is proposed to guarantee the accuracy of the frequency behavior assessment. Further considering that fast frequency controllers potentially degrade the small-signal rotor angle stability, this paper presents a coordinated parameter optimization model of fast frequency controllers, which guarantees the system frequency behavior while meeting the small-signal rotor angle stability requirement. Case studies validate the effectiveness of the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.