Abstract
Intravascular optical coherence tomography is a high-resolution invasive imaging modality that allows the evaluation of vascular responses after stent implantation in a micron-scale level. We describe for the first time two patients with very late vascular response after carotid artery stenting that exhibit two different patterns of low-signal intensity (LSI), "ill-appearing" neointima: the first patient shows layered LSI neointima leading to stent restenosis, coupled with the presence of intraluminal thrombus, whereas the second patient demonstrates another pattern of non-restenotic LSI stent strut coverage, suggestive of lipid laden neointima (ie, "neoatherosclerosis"), recently associated with stent failure in coronary arteries.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.