Abstract

A good insulator for high voltage cable has low dielectric loss, reasonable flexibility and thermo-mechanically stable. However, prolonged application of electrical stresses on the cable will degraded the cable; physically and morphologically. Electrical degradation in high voltage cable can be detected using electroluminescence (EL) method. Electroluminescence is a phenomenon that occurs when the atoms of a material are being excited due to the application of and external high electrical stresses. There are several external factors that affect the behaviour of electroluminescence emission such as, applied voltage, applied frequency, ageing of material and types of materials. . In this paper, the EL measurement is employed to determine the effect of applied frequency on virgin LDPE at fixed and varying applied voltage. It can be observed that EL emission increases as applied frequency increases with increasing voltage applied. However, interesting EL behaviour is observed when varying frequency is applied from 10 Hz to 100 Hz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.