Abstract
This paper presents a fuzzy controller for freeway ramp metering, which uses rules of the form: IF “freeway condition” THEN “control action.” The controller has been designed to consider varied levels of congestion, a downstream control area, changing occupancy levels, upstream flows, and a distributed detector array in its rule base. Through fuzzy implication, the inference of each rule is used to the degree to which the condition is true. Using a dynamic simulation model of conditions0fj at the San Francisco-Oakland Bay Bridge, the action of the fuzzy controller is compared to the existing “crisp” control scheme, and an idealized controller. Tests under a variety of scenarios with different incident locations and capacity reductions show that the fuzzy controller is able to extract 40 to 100% of the possible savings in passenger-hours. In general, the fuzzy algorithm displays smooth and rapid response to incidents, and significantly reduces the minute-miles of congestion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.