Abstract

In this study, our aim was to reveal the effect of the medial femoral offset aimer usage through the femoral tunnel entry and exit points and the tunnel length during femoral tunnel drilling in arthroscopic anterior cruciate ligament (ACL) reconstruction. One hundred patients who underwent arthroscopic single-bundle ACL reconstruction were included in the study. Group 1 consisted of 50 patients who underwent femoral tunnel drilling using a medial portal offset aimer device, while Group 2 consisted of 50 patients who were operated on using the freehand technique. Both groups were compared in terms of femoral tunnel and graft tunnel lengths, femoral tunnel angle in the coronal plane, and the location of the femoral tunnel entry and exit points. The mean femoral tunnel and graft tunnel lengths were significantly longer in Group 2 (p = 0.000). There was no significant difference in terms of localization of the femoral tunnel entry point in both the axial and sagittal planes. The tunnel exit point was located significantly more posterior in Group 1 in the axial plane (p = 0.028). There was no significant difference in terms of the coronal plane femoral tunnel angle between the two groups. In arthroscopic ACL reconstructions, more successful results may be obtained with the freehand technique compared to drilling with a femoral offset aimer. For an experienced orthopedic surgeon, using a medial portal offset aimer device during femoral tunnel drilling does not seem necessary. The online version contains supplementary material available at 10.1007/s43465-023-00929-z.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call