Abstract

We have adapted a new radioimmunoassay for free thyroxin (FT4) measurement in dried blood spots for use in neonatal screening for hypothyroidism. The method is easy, fast, and cheap. Within-assay and between-assay CVs are respectively 9.6% and 13.2%. In 997 neonates three days postpartum with normal thyrotropin concentrations, the mean FT4 concentration was 27.2 pmol/L (SD 7.3 pmol/L). There was no significant difference in mean FT4 concentration between boys and girls. FT4 concentrations increased linearly with birth weight or with gestational age, as expressed by multiple linear regression: FT4 (pmol/L) = 0.0016 birth weight (g) + 0.6931 gestational age (weeks) - 4.8772. Only gestational age significantly affected the FT4 value. For five hypothyroid infants tested on day three postpartum, FT4 values were all below the 1st percentile of values from healthy neonates. Thus, when the neonatal concentration of thyrotropin is above normal, FT4 measured in the same sample can provide a reliable earlier diagnosis of hypothyroidism.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.