Abstract

To determine if porous polyethylene orbital implant (Medpor) exposure can be prevented in retinoblastoma patients when the implant is placed in combination with a free orbital fat graft over the anterior surface of the implant. Free orbital fat grafts were performed after enucleation and Medpor implantation, and results were compared with patients who underwent conventional enucleation and Medpor implantation without an orbital fat graft. Although implant exposure occurred in 13 of 39 eyes (33.3%) that had conventional enucleation and Medpor implantation, exposure did not develop in any of the 38 eyes that had the combined procedure with a free orbital fat graft. These findings suggest that a free orbital fat graft is a simple, effective way to prevent orbital implant exposure in patients requiring enucleation and Medpor implantation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.