Abstract
A quantitative flow cytometry assay was used to evaluate the ex vivo kinetics of c7E3 Fab platelet effect in 16 patients undergoing PTCA treated with abciximab and compared with aggregometry assay. Immunolabeling of platelets was directly assessed on whole blood, using in parallel two monoclonal antibodies (Mabs) raised against GPIIIa, Mab1, the binding of which is inhibited by c7E3 Fab, and Mab2, the binding of which is not affected by c7E3 Fab. We found a severe and sustained inhibition of both GPIIb/IIIa receptors and platelet functions. The inter-individual variation in response to abciximab was low. A significant transient increase at H24 and H48 in the binding of Mab2 was found as an unexpected result, and confirmed in vitro. Results demonstrate that flow cytometry is a reliable method in agreement with aggregation. In addition, our results show that it is a standardized tool and a time-saving technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.