Abstract

The purposes of the study were to introduce surgical technique of fragment-specific fixation technique using multiple 2.7-mm variable-angle locking compression plates (VA LCPs) in comminuted posterior wall acetabular fractures and reported its clinical results. Among the 68 patients, 23 with comminuted posterior wall factures with ≥ 3 fragments in the CT scan and no column involvement with a minimum follow-up duration of 12months were enrolled in this study. We evaluated the clinical results after the treatment of comminuted posterior wall acetabular fractures via the fragment-specific fixation technique using 2.7-mm variable-angle locking compression plates (VA LCPs) retrospectively. The average duration of follow-up was 26.8months. Anatomical reduction was achieved in eighteen patients. Imperfect reduction was achieved in five patients. 22 patients achieved fracture union and one patient underwent revision surgery owing to acute postoperative infection. There were no complications, including loss of reduction, fixative failures, sciatic nerve palsy, heterotopic ossification, and early posttraumatic arthritis among 22 patients. The average functional outcome was measured as 'very good'. Fragment-specific fixation technique using 2.7-mm VA LCPs for comminuted posterior wall acetabular fractures could be an acceptable alternative means of surgical fixation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call