Abstract

We present the case of a delayed pseudoarthrosis resulting from a fracture at the site of a radiographically confirmed anterior cervical fusion following plate removal. In this case, an anterior cervical plate was removed to allow for further surgery at a supra-adjacent level. A modicum of literature exists describing delayed fractures following hardware removal in thoracolumbar fusion constructs. The development of a fracture/pseudoarthrosis following hardware removal at the site of a radiographically confirmed anterior cervical fusion has not been previously reported. We describe the clinical presentation and operative management in the case of this rare and unexpected complication.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.