Abstract

The sensor combination pipes fractured during operation. Through macro and micro morphology observation, energy spectrum analysis, metallographic examination and hardness test, the pipes failure properties and reasons were determined. The results showed that the failure property of dynamic pressure pipe was stress corrosion fracture, and the failure property of the static pressure pipe was corrosion fatigue cracking. The pipes failure was related to the absence of stress relief annealing , and mechanical damage on the pipe surface promoted static pressure pipe failure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.