Abstract

The present study was designed to re-evaluate the radioimmunoassay for desmosine in urine, which is currently used as a measure of elastin metabolism. Using ion exchange chromatography, gel filtration and affinity chromatography it was shown that at least five other compounds in hydrolysates of human urine competed for desmosine in the RIA. Fractionating the urine prior to hydrolysis with acetone removed one of the major contaminants. The other contaminants could subsequently be removed by extracting the urine hydrolysate with a mixture of chloroform/ethanol (60:40). Samples from nine normal adult urines showed that an average of 45% of the RIA competing material in unfractionated urine was not desmosine. The final extracted residue retained all of the desmosine and only 16% of the original solids. The average adult urine contains approximately 50 pmol desmosine/mg creatinine, reflecting a daily turnover of between 3 and 4 mg of elastin per day.