Abstract

This paper discusses the fractionation of human plasma proteins HSA and HIgG by hydrophobic interaction membrane chromatography. A type of microporous polyvinylidine fluoride (PVDF) membrane having 0.1 μm pore size was identified as being suitable for carrying out this separation. This membrane bound HIgG at 1.5 M ammonium sulphate concentration, a condition at which HSA did not. Based on this selective binding resulting from the selective pressure induced by the high anti-chaotropic salt concentration, these human plasma proteins were fractionated. The HIgG binding capacity of the PVDF membrane examined in this study was 42.8 mg/ml at a feed concentration of 0.45 mg/ml. Separation of simulated HSA/HIgG mixtures were carried out in the pulse and step input modes and the HSA and HIgG fractions thus obtained were analysed for purity using affinity chromatography and SDS-PAGE. HSA and HIgG purities were typically in excess of 97–98%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.