Abstract

The quality of output current of LCL-type voltage source inverter (VSI) is degraded by the grid voltage distortion, the dead time effect, and the parameter mismatches. This paper proposes a novel fractional order harmonic disturbance observer-based control (FOHDO) for the three-phase LCL-type inverter to suppress all the dc- and ac-component periodic disturbances. Firstly, a harmonic disturbance observer based control for LCL-type inverter is proposed with the internal model knowledge of the periodic disturbances signals. Subsequently, the FOHDO based on Lagrange interpolating polynomial fractional order delay approximation is put forward to enhance the adaptability of the grid frequency. Then, the stability and robustness performance of the proposed FOHDO for LCL-type inverter are evaluated, which also involves a detailed parameter design process. Finally, the effectiveness and performance of the proposed FOHDO method are verified by both experimental and simulation results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.