Abstract

AbstractFractional gas hold up was measured in gas inducing type of mechanically agitated contactors (GIMAC) with single and multiple impellers. Three vessels of 0.57, 1.0 and 1.5 m i.d. were used. For the multiple impeller system, six different impeller designs were employed. The impeller speed was varied in the range of 0.30 to 15.45 s−1. The ratio of impeller diameter to tank diameter (D/T), the submergence (S) of the upper impeller, the clearance of the lower impeller from the tank bottom (C1) and the impeller spacing (C3) were varied over a wide range. The design of the lower impeller was optimized in terms of diameter (D), blade width (W), blade angle (Bø), number of blades (nb) and the blade thickness (tb). An optimum design has been proposed for the multiple impeller system. Rational correlations have been proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.