Abstract

A burst carrier frequency measurement scheme combined with a timestamping counting method based on a field programmable gate array (FPGA) is proposed. With the multiplication and phase shift of count clock, multiple parallel counters are continuously counted, and the times of the rising edge of the unknown frequency fx are counted simultaneously. To obtain the frequency of fx , linear regression by use of least-squares line fitting is used. Experimental results show that the proposed approach can effectively reduce the error introduced by the quantisation error of ±1, improve measurement accuracy by about 2 to 3 bit, reduce measurement uncertainty by more than 20% and diminish the processing time to 200 ns compared with the traditional methods under the same conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.