Abstract

The method of constant stimuli was used to estimate the psychometric functions for detection of one or two flashes when two light pulses were presented. The test stimulus consisted of two simultaneous 0.5 msec, 1′ pulses separated by 17′. Observers reported seeing 0, 1 or 2 flashes. A computer-controlled direct-view apparatus allowed sampling of slightly different foveal locations on each trial. The data were analyzed assuming a binomial probability for sampling of L and M cones and Poisson distributed quantal fluctuation. Under these assumptions, the measurements imply that detection requires a minimum of 5–7 quanta absorbed per cone, and that the effective number of cones illuminated by the 1′, 0.5 msec pulse is two. The estimated LM cone ratio was 1.6 for one observer and 4.0 for the other; each observer's ratio was in general agreement with the value estimated independently by heterochromatic flicker photometry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.