Abstract

Abstract Fourier Transform Raman spectroscopy can be performed with either a Martin—Puplett interferometer (MPI) or a Michelson interferometer (MI). With linearly polarized exciting light, the MPI provides information on the Stokes parameters S 1 , and S 3 of the scattered Raman light, from a single measurement. The parameter S 1 represents the difference in the scattered intensities with parallel and perpendicular polarizations while S 3 represents the difference in the scattered intensities with right and left circular polarizations. A procedure to extract these parameters with a Michelson interferometer is developed in this paper. A comparison of both approaches indicates that the use of the MPI is favored if the objective is to extract the Stokes parameters. Both approaches are equally favored if the objective is to measure the depolarization ratios. For measuring total Raman scattering, the use of a Michelson interferometer appears preferable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.