Abstract
Fourier transform evaluation for moiré deflectogram is proposed to automatically map the temperature field. The moiré deflectogram is generated by conventional deflectometer and is analyzed by means of Fourier transform algorithm. The convolution backprojection algorithm is used for the optical tomography. Asymmetric 3-D gas temperature distribution for a given layer is reconstructed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.