Abstract

Cognitive dysfunction, including dementia and delirium, is prevalent in geriatric emergency department (ED) patients, but often remains undetected. One barrier to reliable identification of acutely or chronically impaired cognitive function is the lack of an acceptable screening tool. While multiple brief screening instruments have been derived, ED validation trials have not previously demonstrated tools that are appropriately sensitive for clinical use. The primary objective was to evaluate and compare the Ottawa 3DY (O3DY), Brief Alzheimer's Screen (BAS), Short Blessed Test (SBT), and caregiver-completed AD8 (cAD8) diagnostic test performance for cognitive dysfunction in geriatric ED patients using the Mini Mental Status Exam (MMSE) as the criterion standard. A secondary objective was to assess the diagnostic accuracy for the cAD8 (which is an informant-based instrument) when used in combination with the other performance-based screening tools. In an observational cross-sectional cohort study at one urban academic university-affiliated medical center, trained research assistants (RAs) collected patients' responses on the Confusion Assessment Method for the Intensive Care Unit, BAS, and SBT. When available, reliable caregivers completed the cAD8. The MMSE was then obtained. The O3DY was reconstructed from elements of the MMSE and the BAS. Consenting subjects were non-critically ill, English-speaking adults over age 65 years, who had not received potentially sedating medications prior to or during cognitive testing. Using an MMSE score of ≤23 as the criterion standard for cognitive dysfunction, the sensitivity, specificity, likelihood ratios, and receiver operating characteristic (ROC) area under the curve (AUC) were computed. Venn diagrams were constructed to quantitatively compare the degree of overlap among positive test results between the performance-based instruments. The prevalence of cognitive dysfunction for the 163 patients enrolled with complete data collection was 37%, including 5.5% with delirium. Dementia was self-reported in 3%. Caregivers were available to complete the cAD8 for 56% of patients. The SBT, BAS, and O3DY each demonstrated 95% sensitivity, compared with 83% sensitivity for the cAD8. The SBT had a superior specificity of 65%. No combination of instruments with the cAD8 significantly improved diagnostic accuracy. The SBT provided the optimal overlap with the MMSE. The SBT, BAS, and O3DY are three brief performance-based screening instruments to identify geriatric patients with cognitive dysfunction more rapidly than the MMSE. Among these three instruments, the SBT provides the best diagnostic test characteristics and overlap with MMSE results. The addition of the cAD8 to the other instruments does not enhance diagnostic accuracy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.