Abstract

Background and objectiveNeoadjuvant chemotherapy (NAC) is a valuable treatment approach for locally advanced breast cancer. Contrast-enhanced ultrasound (CEUS) potentially enables the assessment of therapeutic response to NAC. In order to evaluate the response accurately, quantitatively and objectively, a method that can effectively compensate motions of breast cancer in CEUS videos is urgently needed. MethodsWe proposed the four-quadrant fast compressive tracking (FQFCT) approach to automatically perform CEUS video tracking and compensation for mice undergoing NAC. The FQFCT divided a tracking window into four smaller windows at four quadrants of a breast lesion and formulated the tracking at each quadrant as a binary classification task. After the FQFCT of breast cancer videos, the quantitative features of CEUS including the mean transit time (MTT) were computed. All mice showed a pathological response to NAC. The features between pre- (day 1) and post-treatment (day 3 and day 5) in these responders were statistically compared. ResultsWhen we tracked the CEUS videos of mice with the FQFCT, the average tracking error of FQFCT was 0.65 mm, reduced by 46.72% compared with the classic fast compressive tracking method (1.22 mm). After compensation with the FQFCT, the MTT on day 5 of the NAC was significantly different from the MTT before NAC (day 1) (p = 0.013). ConclusionsThe FQFCT improves the accuracy of CEUS video tracking and contributes to the computer-aided response evaluation of NAC for breast cancer in mice.