Abstract
It is shown, both through simulations and experiments, that the in-line holographic microscopy technique can be used to retrieve very small refractive-index perturbations caused during the filamentation of ultrashort laser pulses. This technique provides the possibility of having spatially and temporally (four dimensions) resolved measurements of refractive-index changes, down to 10${}^{\ensuremath{-}4}$, from objects with diameters as small as 10 \ensuremath{\mu}m. Moreover, we demonstrate the power of the technique in discriminating multiple filaments in a precise quantitative way.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.