Abstract

Purpose This study aimed to evaluate the effectiveness of four-dimensional (4D) robust optimization for proton pencil-beam scanning (PBS) treatment of lung tumors.Patients and methods In seven patients with lung cancer, proton beam therapy was planned using 4D robust optimization over 4D computed tomography (CT) data sets. The gross target volume (GTV) was contoured based on individual breathing phases, and a 5-mm expansion was used to generate the clinical target volume (CTV) for each phase. The 4D optimization was conducted directly on the 4D CT data set. The robust optimization settings included a CT Hounsfield unit (HU) uncertainty of 4% and a setup uncertainty of 5 mm to obtain the CTV. Additional target dose objectives such as those for the internal target volume (ITV) as well as the organ-at-risk (OAR) dose requirements were placed on the average CT. For comparison, three-dimensional (3D) robust optimization was also performed on the average CT. An additional verification 4D CT was performed to verify plan robustness against inter-fractional variations.Results Target coverages were generally higher for 4D optimized plans. The difference was most pronounced for ITV V70Gy when evaluating individual breathing phases. The 4D optimized plans were shown to be able to maintain the ITV coverage at full prescription, while 3D optimized plans could not. More importantly, this difference in ITV V70Gy between the 4D and 3D optimized plans was also consistently observed when evaluating the verification 4D CT, indicating that the 4D optimized plans were more robust against inter-fractional variations. Less difference was seen between the 4D and 3D optimized plans in the lungs criteria: V5Gy and V20Gy.Conclusion The proton PBS treatment plans optimized directly on the 4D CT were shown to be more robust when compared to those optimized on a regular 3D CT. Robust 4D optimization can improve the target coverage for the proton PBS lung treatments.

Highlights

  • Lung cancer is the second most common malignancy among both male and female populations in the U.S, and it is the leading cause of cancer-related mortality, accounting for one out of four cancer deaths in 2017 [1]

  • The 4D optimized plans were shown to be able to maintain the internal target volume (ITV) coverage at full prescription, while 3D optimized plans could not. This difference in ITV V70Gy between the 4D and 3D optimized plans was consistently observed when evaluating the verification 4D computed tomography (CT), indicating that the 4D optimized plans were more robust against interfractional variations

  • The internal gross tumor volume (IGTV) is defined on the maximum intensity projection (MIP) image to account for the gross target volume (GTV) motion, and the ITV is typically obtained as an expansion of the IGTV

Read more

Summary

Introduction

Lung cancer is the second most common malignancy among both male and female populations in the U.S, and it is the leading cause of cancer-related mortality, accounting for one out of four cancer deaths in 2017 [1]. For IMPT, the effect of breathing motion, i.e., the interplay between the moving lung anatomy and the sequentially delivered proton spots, needs to be mitigated in order to ensure accurate dose distribution [7,8,9,10,11,12,13,14] Strategies such as four-dimensional (4D) robust optimization [15,16], gating [17], repainting [18], compression belt [19], synchronized multi-gating [20,21,22,23] and breath-hold [24] have been shown to provide superior dose distributions for proton lung treatments. We examined the clinical use of 4D robust optimization in a commercially available treatment planning system (TPS) for pencil-beam scanning (PBS) treatment of lung tumors

Objectives
Methods
Results
Discussion
Conclusion