Abstract
BackgroundDistal anastomosis bleeding is an issue during total arch replacement with the frozen elephant trunk technique. We used the 4-branched graft inversion technique for the distal anastomosis in acute aortic dissection. The aim was to evaluate the feasibility and benefits of the technique used during the frozen elephant trunk procedure for acute aortic dissection.MethodsFrom January 2017 to July 2019, 109 patients underwent total arch replacement for type A acute aortic dissections. Patients were divided according to the technique used for the distal anastomosis as follows: group G (n = 57; 4-branched graft inversion technique) and group C (n = 52; conventional method with Teflon felt). The postoperative variables were analysed.ResultsThe hospital mortality rate was 9.2% (10/109). The mean cardiopulmonary bypass, cardiac arrest, and circulatory arrest times were 234.95 ± 71.88 min, 168.25 ± 61.33 min, and 39.19 ± 9.45 min, respectively. The circulatory arrest and cardiac arrest times were shorter in the graft inversion group than in the conventional group (36.46 ± 7.88 min vs. 42.19 ± 10.17 min, P = 0.001 and 156.21 ± 55.99 min vs. 181.44 ± 64.68 min, P = 0.031, respectively). There were 7 cases of stroke (6.4%) and 5 cases of paraplegia (4.6%). Additionally, 13 patients (11.9%) required temporary continuous renal replacement therapy. Respiratory failure occurred in 19 patients (17.4%). There were no significant differences in postoperative complications between the two groups.ConclusionsThe 4-branched graft inversion technique provides effective and confirmed haemostasis during total aortic arch replacement using the frozen elephant trunk procedure.
Highlights
Distal anastomosis bleeding is an issue during total arch replacement with the frozen elephant trunk technique
Acute type A aortic dissection is a surgical emergency with a high mortality rate [1]
We report the first application of this technique in total aortic arch replacement using the frozen elephant trunk (FET) technique for the treatment of acute type A aortic dissection and summarise our experience
Summary
Distal anastomosis bleeding is an issue during total arch replacement with the frozen elephant trunk technique. We used the 4-branched graft inversion technique for the distal anastomosis in acute aortic dissection. The prognosis of total aortic replacement for acute type A aortic dissection is unsatisfactory [2], and bleeding is one of the main reasons. The branched graft inversion technique developed by Tanaka et al [8]. This technique has been only applied to elective thoracic aortic aneurysms. We report the first application of this technique in total aortic arch replacement using the frozen elephant trunk (FET) technique for the treatment of acute type A aortic dissection and summarise our experience
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.