Abstract

Reverse electrodialysis converts electrochemically into energy conversion technology due to the difference in salinity between diluted salt solutions such as seawater and dilute salt solutions such as fresh water. The RED stack has a cation exchange membrane and anion exchange membrane alternately arranged between two electrodes that selectively transmit anions and cations. Ion exchange membranes are easily contaminated with multivalent ions and organic matter, which affects the performance of RED. In this study, the fouling phenomena of cation and anion exchange membranes for various foulants possibly found in seawater and river water were investigated. Ion exchange membranes were contaminated with NaCl solution containing foulants, and the electrical resistance and the degree of contamination with contamination time were measured. The cation exchange membrane is contaminated with a cationic foulants and the anion exchange membrane is contaminated with anionic foulants. The fouled membranes were regenerated, and the electric resistance and the degree of contamination with regeneration time were measured. Acknowledgment This work was conducted under the framework of Research and Development Program of the Korea Institute of Energy Research (KIER) (B8-2441).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call