Abstract
Fouling detection is a relevant problem for chemical, oil, food and pharmaceutical industries. Fouling consists of the deposition of heavy organic materials and other dissolved solids or in suspension in fluid transport system. The ultrasonic guided waves present specific characteristics and have demonstrated good results in detection of flaws in pipelines. This work presents the results of the parameters estimation, based on the Gaussian pulses model, of a system that uses guided waves for fouling detection in pipelines. Initially are made simulations and the use of FFT (Fast Fourier Transformer) of the ultrasound signal is proposed to determine the present frequencies and to reduce the number of parameters estimated. With the obtained estimation model, it intends to observe the modifications of the parameters when the fouling occurs in the monitored pipeline.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.