Abstract

Due to reduced energy efficiency and productivity loss caused by fouled heat exchangers in industrial plants there is an obvious need for detection of fouling formation. Based on continuously measured temperatures and flow rates collected from the refinery plant history database, a semi-empirical number of transfer units (NTU) model and neural network-based models are developed. In order to confirm the reliability of proposed fouling factor calculation, the entire procedure was performed by developing a dynamic nonlinear finite impulse response (NFIR) model. Developed models are intended for fouling detection for industrial shell and tube heat exchangers. The performance criteria of developed models together with residual monitoring indicate that not only neural networks but the NTU and NFIR models effectively detect fouling formation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.