Abstract

The possibilities of the formation of a flammable cloud over the ground in an open atmosphere from the leakage of hydrogen stored at different temperatures are studied. The dispersion of hydrogen in the stable and unstable atmospheric conditions is determined using the Gaussian dispersion model. The efflux of hydrogen from the storage vessel is considered at velocities between 1 m/s and 1500 m/s, the latter corresponding to the upper limit of velocities arising from the choked flow. The dispersion analysis shows that flammable hydrogen–air clouds would not be formed over the ground under unstable atmospheric conditions for all efflux velocities and leakage areas and for the different temperatures of the hydrogen leak. However, under strongly stable atmospheric conditions, such as those associated with clear sky winter nights with low winds and temperature inversion in the planetary boundary layer, a flammable cloud is seen to be formed. This is particularly true for low temperature hydrogen efflux and very low velocities of the efflux.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.