Abstract

Forced mixer lobes in augmentor primary ejectors obtain a 100-percent increase in pumping over conventional design, together with nearly complete mixing in very short mixing ducts, through the generation of large scale axial vorticity in the mixing duct. The vorticity causes rapid mixing of the primary and secondary flows with low losses; since mixing length is minimized, wall friction losses are reduced, allowing more secondary flow to be pumped for a given total pressure in the primary flow. Analytical results are presented that are judged to have significant implications for future ejector test work.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.