Abstract
This paper discusses air forced convection heat transfer from inline protruding elements arranged in eight rows. The streamwise and spanwise spacings between elements were varied using a splitter plate that can be positioned at three different modular configurations. A set of empirical formulas was obtained to correlate the experimental data for air cooling systems design. Arrays of components with one odd-sized module have also been tested. Experimental results show that blocks near the entrance and behind the odd-size module have improved performance compared to uniform arrangements. Accordingly, temperature sensitive components are suggested to be placed in these locations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.