Abstract
Forced convection heat transfer from a low-profile block placed in a rectangular duct, simulating heat transfer in a compact packaged electronic device, is investigated experimentally. Local heat transfer from the block is measured by an infrared camera. A general correlation of the Nusselt number for the block is derived using a modified Reynolds number, ReL*=Um/β2L/ν, where Um is mean duct velocity, β is the opening ratio of the duct, and L is the block length. The correlation is shown to be applicable regardless of the configuration of the block and duct, under the conditions of laminar flow, a low-profile block (height/length<0.5), and a low blockage effect (β⩾0.5).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.