Abstract

The force applied to the teeth is a variable of orthodontic treatment that can be controlled. Poor control of the applied force can lead to adverse biologic effects as well as undesirable tooth movements. The selected archwire-bracket combination is a primary determining factor in the force level applied to a tooth during orthodontic treatment. The aim of this research was to use an experimental biomechanical setup to measure forces generated during complex orthodontic tooth movements with various archwire-bracket combinations. The materials consisted of 3 types of 0.022-in slot orthodontic brackets: (1) conventional brackets (Victory Series [3M Unitek, Monrovia, Calif] and Mini-Taurus [Rocky Mountain Orthodontics, Denver, Colo]), (2) self-ligating brackets (SmartClip [3M Unitek] and Time3 [American Orthodontics, Shegoygan, Wis]), and (3) a conventional low-friction bracket (Synergy [Rocky Mountain Orthodontics]); and 4 archwire types: (1) 0.012-in stainless steel (3M Unitek), (2) 0.0155-in coaxial (Advanced Orthodontics [Näpflein, Düsseldorf, Germany]), (3) 0.012-in Orthonol (Rocky Mountain Orthodontics), and (4) 0.012-in Thermalloy (Rocky Mountain Orthodontics). Stainless steel ligatures and elastomeric rings were used. The materials were used in different combinations in a simulated malocclusion that represented a maxillary central incisor displaced 2 mm gingivally (x-axis) and 2 mm labially (z-axis). The lowest forces were measured when the brackets were combined with either the coaxial or the Thermalloy archwires; the forces ranged from 3.4 ± 0.2 to 0.7 ± 0.1 N in the x-axis direction, and from 4.5 ± 0.3 to 0.5 ± 0.1 N in the z-axis direction. The highest forces were measured in combination with stainless steel archwires; the forces ranged from 6.3 ± 0.3 to 3.0 ± 0.1 N in the x-axis direction, and from 6.3 ± 0.3 to 1.7 ± 0.1 N in the z-axis direction. We recommend 0.0155-in coaxial and 0.012-in Thermalloy archwires for leveling and alignment. Elastomeric rings, when used with conventional brackets, increased the force applied to the teeth.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.