Abstract

The present study proposes an advanced force display control system for a surgical training simulator with virtual reality. In oral and orthopedic surgeries, a surgeon uses a chisel and mallet for chiseling and cutting hard tissue. To enable the representation of force sensation for the chiseling operation in a virtual training simulator, the force display device has been constructed with the ball-screw mechanism to obtain high stiffness. In addition, two-degrees-of-freedom (2DOF) admittance control has been used to react instantaneously to the impactive force caused by pounding with the mallet. The virtual chiseling operation was realized by the force display device with a single axis in the previous studies. In the current study, we propose the design procedure for the force display control system with the 2DOF admittance control approach to virtual operation in three-dimensional space. Furthermore, we propose the design method for the PD controller with imperfect derivative using frequency characteristics for the 2DOF admittance control system. The efficacy of the proposed control system is verified through the virtual experience from manipulating the chisel using the developed force display device in the current study.

Highlights

  • Surgical training simulators enhanced by virtual reality have been developed to enable surgeons to efficiently acquire and improve their surgical skills

  • The force display device used the surgical operation of hard tissue has required high stiffness to withstand the impactive force

  • Comparison between force display control methods The efficacy of the proposed 2DOF admittance control applied on each axis is verified by comparing it with the conventional admittance control [27]

Read more

Summary

Introduction

Surgical training simulators enhanced by virtual reality have been developed to enable surgeons to efficiently acquire and improve their surgical skills. In virtual training systems for soft tissue such as the brain [7], organs and so on [8,9,10], force display devices have used either the serial link mechanism [11,12,13,14] or the parallel mechanism [15,16,17,18]. The force display device used the surgical operation of hard tissue has required high stiffness to withstand the impactive force.

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.