Abstract

In this work, novel modified electrode (MXene/MIL-101(Cr)/GCE) are manufactured through simple layer-by-layer immobilization procedure. The fabricated electrochemical sensor was utilized for electrochemical sensing of flutamide in biological fluids. The immobilization of both MXene and metal-organic framework (MOF) materials on the electrode surface could improve the electrochemical performance of the modified glassy carbon electrode (GCE) towards flutamide due to the synergic effects. The established sensor illustrated the significant sensing ability for the determination of flutamide. The influence of solution pH and volume ratio of MXene/MIL-101(Cr) on electrochemical performance of the modified GCE was researched and optimized. The sensor demonstrated a favorable detection limit of 0.009 μM and a linear range of 0.025–100 μM using differential pulse voltammetry (DPV) technique. The suggested assay illustrated an excellent sensing efficiency towards flutamide in body fluids with recoveries ranging from 97.7% to 102.5%, which indicates its potential in real matrices. In addition, the MXene/MIL-101(Cr)/GCE was illustrated some advantages including simple preparation, good selectivity and reproducibility, and rapid flutamide detection.