Abstract

A two multilayer X-ray mirror system has been developed to focus 8 keV X-rays from a synchrotron X-ray source. The system uses a Kirkpatrick-Baez mirror geometry and the mirrors are made by sputtering carbon and tungsten layers on spherical optical mirror substrates. A focused X-ray spot 40 μm wide by 10 μm high was obtained using an 8 keV X-ray beam from a wiggler beamline at the Stanford Synchrotron Radiation Laboratory. Similar mirror systems may be useful for microprobe and small sample experiments using both synchrotron and laboratory sources.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.