Abstract
This study presents a focused ultrasound solid-liquid extraction (FUSLE) and gas chromatography tandem mass spectrometry method for the determination of brominated diphenyl ethers (BDEs), from mono- to hexa-congeners, in indoor dust. This approach provided a simple, fast, and economical method. After the solvent extraction selection, the FUSLE conditions were studied using a central composite design. Finally, the number of extraction cycles was studied. The selected conditions were 8mL of 3:1 n-hexane-acetone mixture as extraction solvent, at a power of 65% for 20s. The proposed method allowed accurate determination of BDEs, with recovery values around 100% and detection limits between 0.05 and 0.8ngg(-1). It also has advantages over other existing methods in terms of simplicity, analysis time, and solvent consumption. The analysis of several indoor dust samples showed high concentration values of BDEs 47, 99, 100, 153, and 154 in some of the samples, moreover, BDEs 47 and 99 were found in all samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.