Abstract

Femtosecond stimulated Raman spectrometerSection:ChooseTop of pageFemtosecond stimulated Ra... <<Flat-top beam shapersHigh-resolution imaging s...UV lasers for fluorescenc...Neutron imaging system MKS Instruments has launched its Newport femtosecond stimulated Raman spectrometer for scientific research. The nonlinear optical pump–probe instrument combines a narrowband Raman pump, an ultrafast broadband probe, and an ultrafast optical excitation “actinic” pulse. It allows for time-resolved vibrational spectroscopy with simultaneous high spectral and time resolution in the ground and excited states of molecules and yields spectra free from the interference of background fluorescence. Designed to work with amplified femtosecond lasers such as the Spectra-Physics Solstice Ace, the spectrometer can be reconfigured to perform transient absorption spectroscopy and to allow for selected changes such as using an external Raman pump source. MKS Instruments Inc, 2 Tech Dr, Ste 201, Andover, MA 01810, www.mksinst.com Flat-top beam shapersSection:ChooseTop of pageFemtosecond stimulated Ra...Flat-top beam shapers <<High-resolution imaging s...UV lasers for fluorescenc...Neutron imaging system Edmund Optics’ flat-top beam shapers convert collimated Gaussian input beams into collimated flat-top beams with a uniform density distribution and a flat phase front. Featuring an even intensity distribution that is stable over great distances, the converted beam is suitable for microscopy, holography, and system integration. With no internal focusing, flat-top beam shapers are appropriate for applications that require high-power lasers, such as material micromachining. The beam shapers are available with design wavelengths from 266 nm to 10 500 nm for common yttrium aluminum garnet, fiber, and carbon dioxide laser sources. Each operates over a specified wavelength range for laser tuning and can be used with multiple laser sources. Edmund Optics Inc, 101 E Gloucester Pike, Barrington, NJ 08007, www.edmundoptics.com High-resolution imaging spectrographSection:ChooseTop of pageFemtosecond stimulated Ra...Flat-top beam shapersHigh-resolution imaging s... <<UV lasers for fluorescenc...Neutron imaging system Princeton Instruments has added model HRS-500 to its SpectraPro HRS series. The 500 mm focal-length spectrograph and scanning monochromator has an astigmatism-corrected optical system for multichannel fiber applications. The company claims that its spectral deconvolution technology, ResXtreme, optimizes the instrument’s optical performance by improving by as much as 60% the spectral resolution, peak intensities, and consistency across the 2D focal plane. Two exit ports with a full 14 × 30 mm focal plane allow for mounting and operating two array detectors. Applications include Raman spectroscopy, photoluminescence, plasma diagnostics, absorption, and microspectroscopy. Princeton Instruments, 3660 Quakerbridge Rd, Trenton, NJ 08619, www.princetoninstruments.com UV lasers for fluorescence microspectroscopySection:ChooseTop of pageFemtosecond stimulated Ra...Flat-top beam shapersHigh-resolution imaging s...UV lasers for fluorescenc... <<Neutron imaging system Craic Technologies has expanded the capabilities of its 20/30 PV microspectrophotometers by adding deep-UV lasers as excitation sources for them to its laser offerings in the visible to near-IR range. The UV lasers can be used for fluorescence microspectroscopy and can be incorporated into the company’s new photoluminescence package. Both methods require intense light sources, and by exciting in the UV, more materials can be induced to emit photons via a luminescent process. The UV laser output is focused onto a microscopic sample area, and the emitted light is collected and measured by the 20/30 PV microspectrophotometer. The fluorescence or photoluminescence spectra are then analyzed. Craic Technologies Inc, 948 N Amelia Ave, San Dimas, CA 91773, www.microspectra.com Neutron imaging systemSection:ChooseTop of pageFemtosecond stimulated Ra...Flat-top beam shapersHigh-resolution imaging s...UV lasers for fluorescenc...Neutron imaging system << According to Photonis, its Neutronic [i] neutron imaging system provides high resolution and high detection efficiency compared with traditional scintillator-based neutron imaging systems. The system is suitable for physics research, neutron scattering, neutron tomography, and nondestructive testing applications. It uses both cold and thermal neutron imaging techniques to produce still and video images. To achieve neutron sensitivity, Neutronic [i] is equipped with a 100 × 100 mm microchannel plate from Photonis and NeuView technology from Nova Scientific. It houses a vacuum chamber, a high-voltage power supply, and a controller. The system provides short beam-time imaging to protect the items being imaged from damage and can deliver actionable images in under 2 h. Photonis USA Inc, 660 Main St, Sturbridge Business Park, PO Box 1159, Sturbridge, MA 01518, www.photonis.com © 2018 American Institute of Physics.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.