Abstract

To retrospectively compare diffusion-weighted (DW) magnetic resonance (MR) imaging with standard breath-hold T2-weighted MR imaging for focal liver lesion (FLL) detection and characterization, by using consensus evaluation and other findings as the reference standard. Approval for this retrospective HIPAA-compliant study was obtained from the institutional review board; informed consent was waived. Fifty-three consecutive patients (30 men, 23 women; mean age, 60.7 years) with at least one FLL of 1 cm or greater in diameter were evaluated. Two independent observers reviewed DW (b values of 0, 50, and 500 sec/mm(2)) and T2-weighted images for FLL detection and characterization. Reference standard for diagnosis was obtained from consensus review by the two observers of DW, T2-weighted, and dynamic contrast material-enhanced images, pathologic data, and follow-up imaging results. Apparent diffusion coefficient (ADC) was measured for FLLs identified at consensus review. DW and T2-weighted images were compared for FLL detection and characterization by using a binary logistic regression model. Receiver operating characteristic curve analyses were conducted to evaluate the utility of ADC for diagnosis of malignancy. Two hundred eleven FLLs (136 malignant, 75 benign) were detected at consensus review. Overall detection rate (averaged for two observers) was significantly higher for DW (87.7%) versus T2-weighted (70.1%) imaging (P < .001). FLL characterization was not significantly different between DW (89.1%) and T2-weighted (86.8%) imaging (P = .51). ADCs of malignant FLLs were significantly lower than those of benign FLLs (P < .001). The area under the curve for diagnosis of malignancy was 0.839, with sensitivity of 74.2%, specificity of 77.3%, positive predictive value of 85.5%, negative predictive value of 62.3%, and accuracy of 75.3%, by using a threshold ADC of less than 1.60 x 10(-3) mm(2)/sec. DW MR imaging was better than standard breath-hold T2-weighted imaging for FLL detection and was equal to breath-hold T2-weighted imaging for FLL characterization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.