Abstract

The application of multiple-beam shearing interferometry to lens focal-length measurement is described. A coated shearing plate interferometer was used in transmission to produce sharp multiple-beam fringes that rotate as the collimation of the incoming wave front from the lens under test changes. The test lens was used to collimate light from a point source that was translated longitudinally, and the focal length was determined from the rate of rotation of the fringes as the source moved. This method is simple, accurate, and lends itself to automatic determination of focal length.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.