Abstract

Repetitive transcranial magnetic stimulation (rTMS) is a novel, noninvasive method of stimulating selected regions of the brain that has both research applications and potential clinical utility, particularly for depression. To conduct high-quality clinical studies of rTMS, it is necessary to have a convincing placebo (or sham) treatment. Prefrontal rTMS causes cutaneous discomfort and muscle twitching; therefore, an optimal control condition, ie, sham condition, would mimic the cutaneous sensation and muscular discomfort of rTMS without stimulating the brain. Ideally, the quality and intensity of the sham condition would feel identical to the quality and intensity of the rTMS condition, except that the sham would have no effect on cortical activity. We designed and built a focal electrical stimulation system as a sham rTMS condition. Although this electrical sham system is superior to methods used in previous studies, little is known about how the new electrical sham system compares with active rTMS in terms of the level of discomfort and type of sensation it produces. We hypothesized that the electrical sham system may not mirror the experimental condition sufficiently. We studied this hypothesis under single-blind conditions in 15 healthy adults by administering either the real or sham rTMS at high and low intensities while subjects, who were unaware of condition, rated subjective qualities of the stimulation (such as tingling, pinching, and piercing), the scalp location of the perception, and the painfulness of the stimuli. At low-intensity stimulation, the two techniques (active and sham) differ with respect to the subjective quality of the sensation. The differences between real and sham rTMS were less dramatic at higher intensities. The best sham condition that most closely mimics real prefrontal rTMS requires individual titration of the intensity of electrical stimulation across a broad range. Performing this titration without unblinding patients is likely possible, but technically challenging. We propose a new approach to do this. We conclude that it is possible to create a truly indistinguishable sham condition (with appropriate acoustic masking as well), but more work is needed beyond these initial attempts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.