Abstract

Central venous catheters are a frequently used vascular access for hemodialysis. Fibrin sheath formation is a common complication and is associated with catheter malfunction. Although fibrin sheath angioplasty with catheter exchange is a frequently employed procedure, it can be associated with mechanical complications. An important technical step in this procedure is progression of the guide-wire into the inferior vena cava. Focal alveolar hemorrhage is a very rare complication of this procedure. We report a case of a 70-year old patient on dual antiplatelet therapy who underwent fibrin sheath angioplasty with guide-wire catheter exchange and experienced focal alveolar hemorrhage presenting as hemoptysis and acute type 1 respiratory failure. Progression of the guide-wire into the pulmonary circulation and antithrombotic therapy played a significant role in the development of this complication. This report aims to call attention to a poorly described and potentially serious yet avoidable complication of fibrin sheath angioplasty with guide-wire catheter exchange.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.