Abstract

Abstract Results in terms of residual ratios are compared for the batch foam separation from aqueous solution of phenolate, orthophosphate, and dichromate, using a cationic surface-active agent. Effects of pH and of initial surfactant concentration are considered and dichromate is most readily separated. For the single-column foam separation of dichromate in a continuous flow unit, residual ratios are minimized at a feed dichromate concentration of 60 mg/liter, for feed surfactant/dichromate ratios ranging from 3 to 4 g/g. The performances of series, multicolumn units have been calculated in terms of various parameters for feed dichromate concentrations of 25,50, and 100 mg/liter. Better results for single (and multiple) columns could be achieved by using a greater foam height, with the feeds entering at the midpoint of the column of foam.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.